WMV650B Veterinary Patient monitor
12 inch high resolution touchable display for easy reading
Portable design and user-friendly interface for easy operation
تفاصيل المنتج
Features
12 inch high resolution touchable display for easy reading
Portable design and user-friendly interface for easy operation
Flexible configurations to meet different clinical needs
Optional IBP,ETCO2,CO,VGA,printer
Optional CMS function,up to 64 beds
Optional wifi/3G/4G module
Built-in rechargeable Lithium-ion battery for fluid
Built-in rechargeable battery
7 hours continuous working with battery
12 months warranty
مواصفات
Display
12.1” color TFT LCD touch
Screen,resolution: 800 x 600
8 waveform display,12-leads ECG display
Pulse rate
Range: 30~254 bpm
Resolution: 1bpm
Accuracy: ±3bpm (non-motion)
±5bpm (motion)
Refreshing rate: 1s
I/O
LAN: 1 standard RJ45 port
WLAN: IEEE802.11b/g/n USB:2 USB connectors SD: 1 SD card socket
Output:1 connector for nurse
call,Defib sync analog output
VGA: 1 color VGA monitor connector(optional)
NIBP
Measurement method : Automatic oscillometric method
Operating mode:Manual, automatic, continuous Measurement unit: mmHg/kPa selectable
Typical measurement time: 20~40s Measurement type: Systolic, Diastolic,Mean Measurement range (mmHg)
Range of Systolic pressure: Dog 40-270
Cat 40-200
Others 40-135
Range of Diastolic pressure: Dog 10-210
Cat 10-150
Others 10-95
Range of Mean pressure: Cat 20-230
Dog 20-165
Others 20-105
Measurement accuracy
Maximum average error: ±5mmHg
Maximum standard deviation: 8mmHg
Resolution: 1mmHg
Interval:1,2,3,4,5,10,15,30,60,90,120,180,240,48
0minutes Overpressure protection: Software and
hardware,double
safety protection
Cuff pressure range: 0-280mmHg
RESP
Method:Trans-thoracic impedance
Operation modes: Auto/Manual
Measurement range: Adult:0~150 bmp
TEMP
Accuracy: ±0.1℃ or ±0.2℃ °F(without probe)
Measurement range: 5~50℃ (41~122°F)
Channel:Two channels Resolution: 0.1℃
Parameters:T1,T2 and TD
Pulse rate
Range: 30~254 bpm
Resolution: 1bpm
Accuracy: ±3bpm (non-motion) ±5bpm (motion)
Refreshing rate: 1s
SPO2
Measurement range : 0-100%
Resolution: 1%
Accuracy: ±2%(70-100% Cat/Dog);
±3%(70-100%,Others);
0-69%,unspecified Refreshing Rate: 1s
Operation environment
Power: AC 100-250V, 50/60Hz
Temperature: 5-40℃
Humidity: <85%
Optional configuration
Stand or wall type for choose
Thermal printer
IBP
ETCO2
Wifi/3G/4G module
CO
Various external ports(VGA/HDMNurse call, USB, Network, etc
Noted: Before order,please tell which optional function do you need,thanks!